How to Choose Thermal Grease for Electronics
Applications, thermal conductivity, bond-line thickness and installation methods — an engineer-focused selection guide.
Effective cooling depends on more than a heat sink. The contact interface between electronic components and cooling hardware matters too.
Explore Thermal Grease
Where Is Thermal Grease Used?
How Thermal Grease Improves Heat Transfer
Even apparently smooth surfaces contain microscopic irregularities. When a processor, LED module or power semiconductor is mounted against a heat sink, trapped air can increase thermal contact resistance. Silicone thermal grease conforms to surface roughness and helps replace these air pockets with a thermally conductive interface.
Where Thermal Grease Works Best
Thermal grease is generally intended for thin contact interfaces, not large structural gaps or mechanical bonding. Typical uses include CPU/GPU cooling, power semiconductors, LED modules, power supplies and industrial electronics.
How Thermal Grease Reduces Contact Resistance
Filling Microscopic Air Gaps
Thermal grease fills microscopic surface valleys between mating parts, improving thermal contact and allowing heat to pass into the cooling structure.
Understanding Thermal Resistance
For a uniform layer, a simplified conduction model is R = t / (k × A), where t is layer thickness, k is thermal conductivity and A is contact area. Real assemblies also have contact resistance, mounting variation and aging effects.
Why Conductivity Is Not the Only Factor
Higher W/m·K alone does not guarantee lower assembled thermal resistance. A thin, stable bond line and reliable surface contact can be equally important.

OPUTE Thermal Grease: Conductivity Options and Applications
Choosing from the OPUTE Product Range
OPUTE Global lists silicone thermal grease grades for different electronic cooling scenarios. The application descriptions below reflect the supplied storefront product listings; they are not comparative performance guarantees.
| Model | Thermal Conductivity | Applications Listed |
|---|---|---|
| TG-10 | 1.0 W/m·K | General electronic cooling |
| TG-15 | 1.5 W/m·K | ICs, transistors and processors |
| TG-20 | 2.0 W/m·K | LED lighting and aluminum heat sinks |
| TG-35 | 3.5 W/m·K | Power electronics and heat sinks |
| TG-40S | 4.0 W/m·K | CPU, PC cooling and heat sinks |
| TG-45 | 4.5 W/m·K | Power supplies, lighting and home appliances |
| TG-50 | 5.0 W/m·K | Computers, power supplies and electronic cooling |
| GP75 | 7.5 W/m·K | CPU/GPU cooling, IGBT and power modules, LEDs (multiple syringe sizes) |
Note: A 3.0 W/m·K product appears in the supplied storefront screenshot as TC30 Thermal Putty Gap Filler. It is excluded from this conventional thermal grease comparison pending product classification confirmation. Verify current TDS values before final selection.
View OPUTE Thermal Grease CollectionThermal Grease in Electronic Assemblies
CPU & GPU Cooling
Applied between processor heat-spreading surfaces and cooling assemblies. Evaluate thin BLT, mounting pressure and thermal cycling. OPUTE lists TG-40S and GP75 for selected computing applications.
Power Semiconductors
Used at suitable IGBT, MOSFET and power-module cooling interfaces. Check flatness, operating temperature and electrical isolation at the assembly level.
LED Lighting
Improves contact between LED substrates and aluminum heat sinks. OPUTE lists TG-20 and TG-45 for lighting-related applications.
Power Supplies
Supports heat transfer from selected power components to cooling hardware. Evaluate TG-35, TG-45 and TG-50 against actual design requirements.
Industrial Electronics
Useful in closely fitted thermal interfaces in control and power-conversion equipment, subject to vibration and temperature-cycle validation.
EV Charging Electronics
May suit selected OBC and charger power-electronic interfaces when mechanical, thermal and electrical requirements are validated.
Application Methods Affect Material Selection
Match the Application Method to the Material
Depending on formulation and production equipment, thermal grease may be applied by manual spreading, controlled dispensing, or screen/stencil printing. Not every formulation is suitable for every process.

Manual Spreading
Suitable for prototypes and small batches. Control coverage and avoid excessive layer thickness.
Automated Dispensing
Validate flow, deposited volume, pressure and repeatability using production equipment.
Stencil / Screen Printing
Confirm paste rheology, stencil geometry, target BLT and process consistency.
What to Check Before Choosing a Grade
| Selection Factor | Engineering Question |
|---|---|
| Interface geometry | What is the real gap and target BLT? |
| Surface condition | Are contact faces flat, clean and compatible? |
| Assembly pressure | Is mounting pressure consistent over time? |
| Thermal target | What component temperature and thermal resistance are acceptable? |
| Electrical properties | Does the assembly require an independent insulating barrier? |
| Processing | Will the grease be spread, dispensed or printed? |
| Reliability | Are pump-out, oil separation and thermal cycling risks relevant? |
Five Thermal Grease Application Mistakes
- Choosing only by W/m·K: also evaluate BLT, contact resistance and stability.
- Applying too much: excessive thickness may increase resistance or overflow.
- Using grease to fill large gaps: consider a pad, gel or other gap filler instead.
- Ignoring reliability: test thermal cycling, oil separation and potential pump-out.
- Assuming every grade is printable or dispensable: verify processing compatibility.
Thermal Grease vs. Thermal Pad vs. Thermal Gel
| Material | Typical Form | Typical Interface Consideration |
|---|---|---|
| Thermal Grease | Paste | Thin interfaces and microscopic surface gaps |
| Thermal Pad | Preformed compressible sheet | Defined gaps and controlled thickness |
| Thermal Gel | Dispensable soft material | Irregular geometry and selected gap-filling applications |
Frequently Asked Questions
Is 7.5 W/m·K grease always better than 4.5 W/m·K?
No. Achieved BLT, contact pressure, thermal resistance and stability also affect assembled performance.
Can thermal grease be used for LED lighting?
Yes, at suitable thin interfaces between LED substrates and cooling surfaces. Verify the selected grade against the application.
Can thermal grease replace a thermal pad?
Not always. Pads are often more suitable for defined or larger gaps.
Is silicone thermal grease electrically insulating?
Many grades are formulated for electrical insulation, but verify the specific TDS and complete assembly. Do not assume grease alone replaces a required dielectric barrier.
What information helps OPUTE recommend a grade?
Provide component type, interface area, actual gap/BLT, mounting pressure, operating temperature, electrical requirements, application method and reliability expectations.
Find the Right Thermal Grease for Your Electronics
Share your interface geometry, thermal targets, mounting conditions and processing method. Our team can help discuss suitable candidates and sample evaluation.
Explore Products Contact OPUTEImages are illustrative concepts, not actual OPUTE test results or customer installation photographs. Confirm all technical claims and product properties against current TDS and validation testing.