OPUTE 6158-12 Two-Part RTV Silicone Adhesive Sealant for LED & Electronics
6158-12 (A/B) Two-Part RTV Silicone Adhesive Sealant
OPUTE 6158-12 (A/B) is a two-component, condensation-curing silicone adhesive sealant designed for bonding, sealing and fixing LED lighting, power supplies, electronic assemblies and compatible metal or plastic housings. The material is mixed at an A:B weight ratio of 1:1 and cures at room temperature. Its manufacturer TDS describes resistance to temperature changes, moisture, UV aging and vibration, along with electrical insulation properties.
Key Features & Benefits
- Two-part room-temperature cure: condensation-curing silicone system mixed A:B = 1:1 by weight.
- Bonding and sealing: suitable for selected lighting assemblies, electronic components and metal or plastic housings.
- Electrical insulation: dielectric strength ≥17 kV/mm and volume resistivity ≥1.0 × 1014 Ω·cm per manufacturer TDS.
- Flexible cured elastomer: Shore A hardness 40 ± 5 and elongation at break ≥200%.
- Environmental durability: manufacturer describes moisture resistance, UV aging resistance and vibration resistance; validate under actual service conditions.
Typical Applications
- LED luminaires and floodlight bonding or sealing
- Power supply and PCB assembly sealing or component fixing
- Electrical insulation and fixing of electronic accessories
- Bonding and sealing of selected aluminum, PC, ABS, PPO, PET and PVC components
- Small appliances and electronic housings
Technical Specifications
Manufacturer-reported reference values from OPUTE 6158-12 (A/B) TDS (A/1, 2026-06-05). Confirm suitability through application-specific testing.
| Property | Reported Value | Test Method / Conditions |
|---|---|---|
| Appearance | A: Black / White / Gray; B: White paste | Visual |
| Mixing ratio by weight | A:B = 1:1 | Application-system measurement |
| Relative density | 1.4–1.45 g/cm³ | GB/T 533-2008 |
| Extrudability at 50 psi | A: 80–110; B: 70–100 g/10 s | GB/T 13477.4-2002 |
| Working time at 25°C | 5–10 min | Application measurement |
| Tack-free time at 25°C | 10–20 min | GB/T 13477.5-2002 |
| Initial cure at 25°C | 1–2 h | Application measurement |
| Full cure time (TDS table) | 24 h | 25°C; see cure note below |
| Cure chemistry | Alcohol-releasing condensation type | Manufacturer TDS |
| Shore A hardness | 40 ± 5 | GB/T 531.1-2008 |
| Dielectric strength | ≥17 kV/mm | GB/T 1695-2005 |
| Dielectric constant at 1.2 MHz | ≤4.0 | GB/T 1693-2007 |
| Volume resistivity | ≥1.0 × 1014 Ω·cm | GB/T 1692-2008 |
| Service temperature | -40 to +200°C | Manufacturer TDS |
| Elongation at break | ≥200% | GB/T 528-2009 |
| Tensile strength | ≥1.5 MPa | GB/T 528-2009 |
| Shear strength | ≥1.8 MPa | GB/T 7124-2008 |
Cure-time clarification: The manufacturer TDS lists 24 h full cure in its parameter table, while a note beneath the table states 7 days for complete cure at 25°C and 55% relative humidity. Cure time depends on assembly geometry and process conditions. Confirm the applicable criterion with OPUTE before specifying a production cycle.
Compliance & Test Reports
The 6158-12 TDS states RoHS and REACH compliance. The report cover images below are reference previews previously used for other OPUTE materials, not grade-specific evidence for 6158-12. Request the corresponding 6158-12 test reports for verification. No halogen-free claim is made for this grade.
Laboratory findings are specific to the samples and scopes named in each original report. These preview images do not establish 6158-12 compliance or certification.
Packaging & Storage
- TDS lists 2600 mL / approximately 3.6 kg per cartridge, four cartridges per carton.
- TDS also lists 25 kg packaging for A/B components; confirm the supplied set configuration and total weight before ordering.
- Store tightly sealed in a cool, dry place at 25 ± 5°C; stated shelf life is 6 months.
- Keep both components sealed between uses. Remove any small cured plug at the Part B outlet before reuse, if applicable.
- Do not store near heat sources, ignition sources or incompatible materials.
Application & Curing Guidelines
- Surface preparation: remove oil, dust, rust and other contamination; ensure bonding surfaces are clean.
- Mix: dispense Part A and Part B at a 1:1 weight ratio using suitable mixing equipment.
- Apply: dispense the mixed silicone onto the prepared interface and assemble the components within the working time.
- Cure: allow curing under suitable ambient conditions; TDS references 25°C and 55% relative humidity. Verify full cure before putting assemblies into service.
- Handle safely: maintain ventilation, wear eye protection and suitable gloves, and avoid skin or eye contact. Follow the current MSDS.
Mix only what can be used within the 5–10 minute working time at 25°C. Higher temperatures may shorten working time; lower temperatures may extend it. Do not reuse mixed material after it begins to cure. The supplied TDS does not specify thermal conductivity, so this product is not represented here as a thermally conductive adhesive.
Need a Two-Part Silicone Bonding & Sealing Solution?
Contact OPUTE for 6158-12 technical information, mixing guidance, sample availability, packaging options and quotations.
Request a QuoteTechnical sources: OPUTE 6158-12 (A/B) TDS, revision A/1, dated 2026-06-05; OPUTE 6158-12 (A/B) MSDS, revision A/0, dated 2026-06-05. Reported values are reference specifications. Confirm the latest documents, curing criteria, packaging and grade-specific compliance reports before purchase.